Appendix 6 Universal Serial Communications App6-15
2. The [Comm. Parameter] dialog comes up. In the [Main 1], [Main 2], and [Detail] tab windows, set
the baud rate, the signal level, etc.
When using multi-drop, go to the [Detail] tab window, check [1 : n] for [Connection], and enter
[Local No].
It is possible to set the transmission mode by going to the [Detail] tab window and making
settings for [Trans. Mode].
Setting Items
Baud Rate
Set the communication speed between the host and the V series. The possible speed settings are
shown below.
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
76800 bps
115 kbps
Signal Level
Set the communication level between the host and the V series.
RS-232C/RS-422