Cable Electronics DVP14 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Procesory Cable Electronics DVP14. Cable Electronics DVP14 Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 332
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 2 - Record of Revisions

31. Yamatake PLCAvailable PLCs ...

Strany 3

16. MITSUBISHI ELECTRIC PLC 16-116. MITSUBISHI ELECTRIC PLCAvailable PLCsA Series Link, QnA Series Link, QnH (Q) Series Link, A Link + Net10*1*1 For

Strany 4

16-2 16. MITSUBISHI ELECTRIC PLCA Series CPU, QnA Series CPU, QnH Series CPU, Q00J/00/01 CPUFX Series*1 For more information of V-MDD (dual port int

Strany 5

16. MITSUBISHI ELECTRIC PLC 16-3Communication SettingThe recommended communication parameter settings of the PLC and the V7 series are as follows:A S

Strany 6

16-4 16. MITSUBISHI ELECTRIC PLCA Series CPU, QnA Series CPUCommunication parameters for the V7 series are automatically set.QnH (A) Series CPU, QnH

Strany 7 - Contents

16. MITSUBISHI ELECTRIC PLC 16-5A Series Link, QnA Series Link: Switch SettingThe following is an example that shows the settings for both rotary DIP

Strany 8

16-6 16. MITSUBISHI ELECTRIC PLCA1SJ71UC24-R4, A1SJ71C24-R4Example 4 Signal level: RS-422, baud rate: 19200 bps, transmission mode 1Available Memory

Strany 9

16. MITSUBISHI ELECTRIC PLC 16-7FX Series, FX1S Series*1 For numerical data format where double-words can be used (Num. Data Display, Graph, Sampling

Strany 10

16-8 16. MITSUBISHI ELECTRIC PLCFX Series (A Protocol)*1 CN200 to CN255 equals 32CN (32-bit counter).*2 For numerical data format where double-words

Strany 11 - Connection Compatibility List

16. MITSUBISHI ELECTRIC PLC 16-9Wiring Diagram 2Wiring Diagram 3PLCRDSDRSCSDRSG3245678CD123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.D-

Strany 12 - 1. Before Connecting to PLC

16-10 16. MITSUBISHI ELECTRIC PLCWiring Diagram 4RS-422Wiring Diagram 5PLCSDRDSG237123457SDRDRSCSSGSHELL875*1D-sub 25-pin (male)* Use shielded twist

Strany 14 - Notes on Connection

16. MITSUBISHI ELECTRIC PLC 16-11Wiring Diagram 6Wiring Diagram 7PLCRDASGRDB2715SDB 16SDA 34517182021DSRADTRADSRBDTRB1712132425SG+SD-SD+RD-RD51278SHE

Strany 15 - CN1 CN1 CN1 CN1

16-12 16. MITSUBISHI ELECTRIC PLCWiring Diagram 8According to our noise tests, the attachment of a ferrite core improves noise voltage by 650 to 900

Strany 16 - Interface

16. MITSUBISHI ELECTRIC PLC 16-13A Link + Net10• When the V7 series is connected to the standard type link unit on the CPU that is connected to the d

Strany 17 - Slide Switch

16-14 16. MITSUBISHI ELECTRIC PLC• Network specifying macro... [OUT_ENQ] of system call [SYS]F1 memory“n + 0” and “n + 1” are fixed to “

Strany 18 - RJ-45 8-pin

16. MITSUBISHI ELECTRIC PLC 16-15V-MDD (Dual Port Interface)V-MDD is the add-on connector with two ports, specifically designed for the connector on

Strany 19 - Wiring (1 : 1 Connection)

16-16 16. MITSUBISHI ELECTRIC PLCConnection• When connecting the V7 series (CN1) to the PLC (CPU port), use a 1 : 1 communication cable as previousl

Strany 20

16. MITSUBISHI ELECTRIC PLC 16-17Settings and Communications1. PLC type settingSelect [PLC Type] from the [System Setting] menu. Select a type adapt

Strany 21 - Send delay

16-18 16. MITSUBISHI ELECTRIC PLC- Enabling V-SFT communications manuallyHold down the F2 switch for three seconds. [Editor: ...] changes to [Edito

Strany 22 - 1st byte 2nd byte

16. MITSUBISHI ELECTRIC PLC 16-19Notes on Ladder Transfer Function1. When [Ladder Tool] is selected for a modular jack, monitor registration on the P

Strany 23

16-20 16. MITSUBISHI ELECTRIC PLCPlease use this page freely.

Strany 24 - Screen No. 0

1. Before Connecting to PLC 1-11. Before Connecting to PLCTypes of ConnectionThere are four types of connection between MONITOUCH(es) and PLC(s).1 :

Strany 25

17. MODICON PLC 17-117. MODICON PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series a

Strany 26 - 2. Allen-Bradley PLC

17-2 17. MODICON PLCWiringWiring diagram with the PLC is shown below.RS-232CWiring Diagram 1PLCRXTXDTR234GND 5DSR 6RTS 7CTS 8123457SDRDRSCSSGSHELL87

Strany 27

18. MOELLER PLC 18-118. MOELLER PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series a

Strany 28 - PLC-5 Series: Switch Setting

18-2 18. MOELLER PLCWiringWiring diagram with the PLC is shown below.RS-232CWiring Diagram 1TXRXSGPLC325123SDRDSHELL87*17SG 5* Use shielded twist-pa

Strany 29 - 1770-KF2

19. OMRON PLC 19-119. OMRON PLCAvailable PLCsSelect PLC Type PLC Unit/Port Connection PLC2WaySYSMAC CC20H,C28H,C40HCPU unit with built-in port(host l

Strany 30 - CPU Port Channel 0

19-2 19. OMRON PLC*1 Replace the shell on the D-sub 25-pin side before use. (Recommended part: DDK’s 17J-25)*2 For connection to MJ2 of a V706, use

Strany 31

19. OMRON PLC 19-3Example:• Setting procedure: Num. Data Display [Input Type] BCD[Display Type] DEC (w/ −sign, w/ +−signs)Available MemoryThe avai

Strany 32

19-4 19. OMRON PLCSYSMAC CS1/CJ1, SYSMAC CS1/CJ1 DNA*1 When using EMn (extended data memory), specify the bank number (CS1: 0 to C).The assigned mem

Strany 33

19. OMRON PLC 19-5Wiring Diagram 2Wiring Diagram 3RSSDCSSG2459RD 3PLC123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.D-sub 9-pin (male)D-s

Strany 34

19-6 19. OMRON PLCRS-422Wiring Diagram 4Wiring Diagram 5SDBRDBRDASDA1569PLCSG 31712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.

Strany 35

1-2 1. Before Connecting to PLC1 : n Connection (Multi-drop)OutlineOne V7 series is connected to multiple PLCs. (Maximum connectable PLCs: 31)Notes

Strany 36 - 3. Automationdirect PLC

19. OMRON PLC 19-7Wiring Diagram 6Wiring Diagram 7SDBRDBRDASDA8261PLCSG 945RSCS1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D

Strany 37

19-8 19. OMRON PLCSYSMAC CS1/CJ1 DNAWhen connecting the V7 series to CS1/CJ1 on a network (Controller Link), the V7 series can also access another C

Strany 38

20. SAIA PLC 20-120. SAIA PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are as

Strany 39

20-2 20. SAIA PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2RXTXGNDPLC325PGU port123SDRDSHELL87*17SG

Strany 40

20. SAIA PLC 20-3RS-485Wiring Diagram 3T/R+T/R−PLCGND101211PCD7.F1101712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D-sub 25-pin

Strany 41

20-4 20. SAIA PLCPlease use this page freely.

Strany 42 - 4. Baldor PLC

21. SAMSUNG PLC 21-121. SAMSUNG PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series a

Strany 43

21-2 21. SAMSUNG PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1RS-422Wiring Diagram 2TXDPLCRXD235GND123457SDRDRSCSSGS

Strany 44 - 5. DELTA PLC

22. SHARP PLC 22-122. SHARP PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are a

Strany 45

22-2 22. SHARP PLCJW100/70H COM Port, JW20 COM Port: System Memory SettingThe settings for communications with the V7 series should be made at the s

Strany 46 - 6. FANUC PLC

1. Before Connecting to PLC 1-3n : 1 Connection (Multi-link 2)Outline• One PLC is connected to a maximum of four V7 series.• An original network is c

Strany 47

22. SHARP PLC 22-3WiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2SXDRXDCTS235RTS 4PLCSG 71214123457SDRDRSC

Strany 48

22-4 22. SHARP PLCRS-422Wiring Diagram 3Wiring Diagram 4Wiring Diagram 5+TXD−TXD−RXD101113+RXD 12PLC1SHELL*112132425+SD-SD+RD-RD1278* Use shielded t

Strany 49

23. SHINKO ELECTRIC PLC 23-123. SHINKO ELECTRIC PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and

Strany 50 - 7. FATEK AUTOMATION PLC

23-2 23. SHINKO ELECTRIC PLCWiringWiring diagram with the PLC is shown below.RS-232CWiring Diagram 1SDPLCRDRS234CS 5SG 7123457SDRDRSCSSGSHELL875*1*

Strany 51

24. Siemens PLC 24-124. Siemens PLCAvailable PLCs*1 When using the 6ES5 734-1BD20 cable made by SIEMENS, connect the cable shown in [Wiring Diagram 3

Strany 52

24-2 24. Siemens PLCS5, S5 V4 (S5-115U, S5-135U, S5-155U), S7 (S7-300, S7-400)S5 PG PortCommunication parameters are automatically set.S7-200PPIS7-

Strany 53

24. Siemens PLC 24-3S7-300MPI (HMI ADP, PC ADP, Helmholz SSW7 ADP)• Set [MPI SETTING] in the [Comm. Parameter] dialog of the V-SFT editor.Highest MPI

Strany 54 - 8. Fuji Electric PLC

24-4 24. Siemens PLCAvailable MemoryThe available memory setting range varies depending on the PLC model. Be sure to set within the range available

Strany 55 - Character switches

24. Siemens PLC 24-5S5 PG PortThe assigned memory is indicated when editing the screen as shown on the right.S7-200PPIS7-300/400MPIThe assigned memo

Strany 56

24-6 24. Siemens PLCTI500/505 (TI500/505 V4)*1 In case of using DCP (drum count/set value), set drum step No.1 to 16.The assigned memory is indicate

Strany 57 - 8-4 8. Fuji Electric PLC

1-4 1. Before Connecting to PLCn : 1 Connection (Multi-link)Outline• One PLC is connected to multiple V7 series. (Maximum connectable V series: 31)

Strany 58

24. Siemens PLC 24-7WiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2TXDPLCRXDGND237123457SDRDRSCSSGSHELL875

Strany 59

24-8 24. Siemens PLCWiring Diagram 3Wiring Diagram 4TXDPLCRXD234GND576ES5 734-1BD20S5-95U123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.

Strany 60 - 9. GE Fanuc PLC

24. Siemens PLC 24-9Wiring Diagram 5RS-422Wiring Diagram 6FGSDRDRSCS12345RDSDSGRTS2357CTS 8SG 7* Use shielded twist-pair cables.HMI AdaptorPC Adaptor

Strany 61

24-10 24. Siemens PLCWiring Diagram 7• Terminating Resistance SettingSet the DIP switch 7 of the V series (for V706: No. 3) to the OFF position.Conn

Strany 62

24. Siemens PLC 24-11Wiring Diagram 8Wiring Diagram 9PLCGNDDI+65DI 8DO+ 1DO 71712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D-s

Strany 63

24-12 24. Siemens PLCPlease use this page freely.

Strany 64 - 10. Hitachi PLC

25. TAIAN PLC 25-125. TAIAN PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are a

Strany 65 - HIDIC-H: Switch Setting

25-2 25. TAIAN PLCWiringWiring diagrams with the PLC are shown below.RS-422Wiring Diagram 1Wiring Diagram 2T/R+T/RSHLDPLC1712132425SG+SD-SD+RD-RD512

Strany 66 - HIDIC-S10/ABS

26. Telemecanique PLC 26-126. Telemecanique PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the

Strany 67

26-2 26. Telemecanique PLCWiringWiring diagram with the PLC is shown below.RS-485Wiring Diagram 1D+D−PLC10V 721712132425SG+SD-SD+RD-RD51278SHELL*1*

Strany 68

1. Before Connecting to PLC 1-5InterfaceCN1 (D-sub 25-pin) (V7 series and V706 + DU-01)The following connector is recommended.CN1 (D-sub 25-pin, fema

Strany 69

27. TOSHIBA PLC 27-127. TOSHIBA PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series a

Strany 70 - 11. IDEC PLC

27-2 27. TOSHIBA PLCAvailable MemoryThe available memory setting range varies depending on the PLC model. Be sure to set within the range available

Strany 71

27. TOSHIBA PLC 27-3WiringWiring diagrams with the PLC are shown below.RS-422Wiring Diagram 1Wiring Diagram 22PLC34RXATXACTSARTSA5SG710111213RXBTXBCT

Strany 72 - 12. KEYENCE PLC

27-4 27. TOSHIBA PLCPlease use this page freely.

Strany 73

28. TOSHIBA MACHINE PLC 28-128. TOSHIBA MACHINE PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and

Strany 74 - KV10/24 CPU

28-2 28. TOSHIBA MACHINE PLCWiringWiring diagram with the PLC is shown below.RS-232CWiring Diagram 1TXDRXDPLCDTRGND2345DSRCTS678RTS123457SDRDRSCSSGS

Strany 75

29. Toyoda Machine Works PLC 29-129. Toyoda Machine Works PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of t

Strany 76

29-2 29. Toyoda Machine Works PLCAvailable MemoryThe available memory setting range varies depending on the PLC model. Be sure to set within the ra

Strany 77

29. Toyoda Machine Works PLC 29-3WiringWiring diagram with the PLC is shown below.RS-422Wiring Diagram 1+0VPLC1712132425SG+SD-SD+RD-RD51278SHELL*1* U

Strany 78

29-4 29. Toyoda Machine Works PLCPlease use this page freely.

Strany 79

1-6 1. Before Connecting to PLCMJ2 (V706 only)*1 Switch between RS-232C and RS-422 for pin Nos. 1, 2, 7, and 8 with the slide switch on the MONITOUC

Strany 80 - 13. KOYO ELECTRONICS PLC

30. VIGOR PLC 30-130. VIGOR PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are a

Strany 81

30-2 30. VIGOR PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1RS-485Wiring Diagram 2PLCRXDTXDSGRTS2357CTS 8123SDRDSHEL

Strany 82 - Switch Setting

31. Yamatake PLC 31-131. Yamatake PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series

Strany 83

31-2 31. Yamatake PLCWiringWiring diagram with the PLC is shown below.RS-232CWiring Diagram 1PLCSDRDRS234CS 5SG 7123457SDRDRSCSSGSHELL875*1* Use shi

Strany 84

32. Yaskawa Electric PLC 32-132. Yaskawa Electric PLCAvailable PLCs* Other PLCs can also be connected with Memobus.Communication SettingThe recommend

Strany 85

32-2 32. Yaskawa Electric PLCCP9200SH/MP900Available MemoryThe available memory setting range varies depending on the PLC model. Be sure to set wit

Strany 86

32. Yaskawa Electric PLC 32-3WiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2TXDRXDRTSCTSDSRSGNDDTR2345679P

Strany 87

32-4 32. Yaskawa Electric PLCWiring Diagram 3Wiring Diagram 4SDRDRSCSDR23456CP217IF(CN1)217IF(CN1/2)SGCD79123457SDRDRSCSSGSHELL875*1* Use shielded t

Strany 88 - 14. LG PLC

32. Yaskawa Electric PLC 32-5RS-422Wiring Diagram 5Wiring Diagram 6TXD+RXD+RXDSGTXDPLC236791712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-p

Strany 89

32-6 32. Yaskawa Electric PLCWiring Diagram 7Wiring Diagram 8RXRX+TXTX+CP217IF (CN3)12671SHELL*112132425+SD-SD+RD-RD1278* Use shielded twist-pair ca

Strany 90 - GLOFA CNET / GM Series CPU

1. Before Connecting to PLC 1-7Connection between MJ2 and PLCThere are two connection methods.• With MJ2-PLCOne method uses an adaptor MJ2-PLC for co

Strany 91

33. Yokogawa Electric PLC 33-133. Yokogawa Electric PLCAvailable PLCs*1 The CPUs that can be connected directly to the programming tool port on the C

Strany 92

33-2 33. Yokogawa Electric PLCCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are as follows:FA50

Strany 93

33. Yokogawa Electric PLC 33-3Available MemoryThe available memory setting range varies depending on the PLC model. Be sure to set within the range

Strany 94

33-4 33. Yokogawa Electric PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2SDRDRSCSDRSGER23456720PLC123

Strany 95

33. Yokogawa Electric PLC 33-5RS-422Wiring Diagram 3RDBRDASDBSDASGPLC1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D-sub 25-pi

Strany 96 - Available PLCs

33-6 33. Yokogawa Electric PLCPlease use this page freely.

Strany 97

Appendix 1 PLC2Way App1-1Appendix 1 PLC2WayPLC2Way• The “PLC2Way” function is an original network function where one V7 series can be connected to tw

Strany 98

App1-2 Appendix 1 PLC2Way• With the PLC2Way function, it is possible to communicate with PLCs without special program in the same way as 1 : 1 conne

Strany 99

Appendix 1 PLC2Way App1-3PLCs Compatible with PLC2Way Connection at MJ Port• When connecting the V7 series to the PLC at the MJ port using PLC2Way fu

Strany 100 - 16. MITSUBISHI ELECTRIC PLC

App1-4 Appendix 1 PLC2WayWiringTwo kinds of cables are available for PLC2Way connection at the MJ port. Cable connections are explained.Connecting

Strany 101 - FX Series

1-8 1. Before Connecting to PLC Wiring (1 : 1 Connection)Prepare the communication cable with the PLC on your side.Refer to the following informatio

Strany 102 - Communication Setting

Appendix 1 PLC2Way App1-5<RS-485 Connection>• Connection example with MITSUBISHI A1SJ71UC24-R4 (1 set)• Connection example with MITSUBISHI A1SJ

Strany 103 - FX Series Link (A Protocol)

App1-6 Appendix 1 PLC2WayFor V706:• The terminating resistance should be set on the DIP switch in the side of the unit.• Set DIPSW1 to the ON positi

Strany 104 - A1SJ71C24-R2, A1SJ71UC24-R2

Appendix 1 PLC2Way App1-73. Select the MJ port.Click the [Refer to Modular] button. The [Modular Jack] dialog is displayed.Select [Temp./PLC2Way] fo

Strany 105 - Available Memory

App1-8 Appendix 1 PLC2Way5. Set the parameters for the PLC to be connected at the MJ port.[Baud Rate] (4800, 9600, 19200, 38400, 57600, 115k, bps)Se

Strany 106 - FX2N Series

Appendix 1 PLC2Way App1-9Code and Text ProcessingFor the PLC connected at the MJ port, code and text processing cannot be set in the [Temp. Control/P

Strany 107 - Wiring Diagram 1

App1-10 Appendix 1 PLC2WayV-SFT Setting When the Temperature Control Network/PLC2Way Table is Used:The following operations are available when the

Strany 108 - Wiring Diagram 3

Appendix 1 PLC2Way App1-112. ClosingClick [Close] in the drop-down menu, or click the [Close] button at the top right corner.3. Comment settingThere

Strany 109 - Wiring Diagram 5

App1-12 Appendix 1 PLC2WayWhen (2) is clicked, a data type for the PLC2 memory can be set.[Word]This is the data length setting for the memory addre

Strany 110 - Wiring Diagram 7

Appendix 1 PLC2Way App1-13When (3) is double-clicked, the [Temp. CTRL/PLC2Way Table Setting] dialog is displayed.Set the memory addresses of the targ

Strany 111 - Wiring Diagram 8

App1-14 Appendix 1 PLC2WayData Sampling in the PLC2 MemoryTo perform data sampling in the PLC2 memory, the following settings are required.• Tempera

Strany 112 - A Link + Net10

Record of RevisionsReference numbers are shown at the bottom left corner on the back cover of each manual.Printing Date Reference No. Revised Contents

Strany 113

1. Before Connecting to PLC 1-9RS-422/485 Connection• Connect twisted pairs between +SD/−SD and +RD/−RD.• If the PLC has the terminal for signal grou

Strany 114 - Ladder Transfer Function

Appendix 1 PLC2Way App1-152. Memory card settingWhen [SRAM] or [CF Card] is selected for [Store Target] in the [Buffering Area Setting] dialog, the m

Strany 115 - CPU port

App1-16 Appendix 1 PLC2WayData Transfer from the PLC2 MemoryData in the PLC2 memory can be transferred to the PLC memory, V7 internal memory or a me

Strany 116 - Settings and Communications

Appendix 1 PLC2Way App1-17Indirect Memory DesignationIt is possible to have access to the PLC2 memory using the indirect memory designation as a macr

Strany 117 - Editor: ... Editor: MJ1

App1-18 Appendix 1 PLC2WayProcessing CycleThe processing cycle on the V7 series with the PLC2Way function is explained.1. When the temperature contr

Strany 118

Appendix 1 PLC2Way App1-19Notes on Screen Data TransferTemperature Control/PLC2 ProgramWhen using the temperature control network/PLC2Way communicati

Strany 119 - Please use this page freely

App1-20 Appendix 1 PLC2WaySystem MemoryThe status of the PLC connected at the MJ port for PLC2Way communications is output to the system memory ($s)

Strany 120 - 17. MODICON PLC

Appendix 1 PLC2Way App1-21Details• $s729An execution result of macro command TEMP_READ, TEMP_WRITE, or TEMP_CTL is stored at this address.- [0]: A co

Strany 121

App1-22 Appendix 1 PLC2Way• $s762Periodical reading that is set in the [Temp. CTRL/PLC2Way Table Setting] dialog can be suspended.- [0]: Periodical

Strany 122 - 18. MOELLER PLC

Appendix 2 n : 1 Connection (Multi-link 2) App2-1Appendix 2 n : 1 Connection (Multi-link 2)Multi-link 2• One PLC is connected to a maximum of four V7

Strany 123

App2-2 Appendix 2 n : 1 Connection (Multi-link 2)• This multi-link connection is available with almost all the PLC models that support 1 : 1 connect

Strany 124 - 19. OMRON PLC

1-10 1. Before Connecting to PLCV-SFT Setting (1 : 1 Connection)For serial communications, the following settings on the V-SFT editor are required.T

Strany 125

Appendix 2 n : 1 Connection (Multi-link 2) App2-3* When the terminal converter “TC485” is not used, install jumpers between +RD/+SD and −RD/−SD.For V

Strany 126

App2-4 Appendix 2 n : 1 Connection (Multi-link 2)(d)(e) Connection between terminal blocksUse the RS-485 2-wire connection.(b)(c)(d)(e) The maximum

Strany 127

Appendix 2 n : 1 Connection (Multi-link 2) App2-5Terminating Resistance SettingFor V7 Series:• The terminating resistance of the V7 series should be

Strany 128

App2-6 Appendix 2 n : 1 Connection (Multi-link 2)For V706:• The terminating resistance of the V706 should be set on the DIP switch.• When the PLC an

Strany 129

Appendix 2 n : 1 Connection (Multi-link 2) App2-7Communication Parameter Setting• Setting Procedure[System Setting] → [Comm. Parameter] → [Comm. Para

Strany 130

App2-8 Appendix 2 n : 1 Connection (Multi-link 2)Please use this page freely.

Strany 131 - SYSMAC CS1/CJ1 DNA

Appendix 3 n : 1 Connection (Multi-link) App3-1Appendix 3 n : 1 Connection (Multi-link)Multi-link• One PLC is connected to multiple V7 series. (Maxi

Strany 132 - 20. SAIA PLC

App3-2 Appendix 3 n : 1 Connection (Multi-link)WiringConnection with Link UnitFor V7 Series:Use the RS-485 2-wire connection.(It is recommended that

Strany 133

Appendix 3 n : 1 Connection (Multi-link) App3-3For V706:For V706 + DU-01, refer to “For V7 Series:” above.Since MJ2 is adapted to 4-wire connection,

Strany 134

App3-4 Appendix 3 n : 1 Connection (Multi-link)When Connecting Directly to the CPU of the MITSUBISHI QnA Series:Use the GD port of Hakko Electronics

Strany 135

1. Before Connecting to PLC 1-11Choose the action to be taken against communication errors.[Comm. Err. Handling]Set error handling routine in the cas

Strany 136 - 21. SAMSUNG PLC

Appendix 3 n : 1 Connection (Multi-link) App3-5V-SFT SettingThe following settings must be made on the V-SFT editor.Only the points different from th

Strany 137

App3-6 Appendix 3 n : 1 Connection (Multi-link)Please use this page freely.

Strany 138 - 22. SHARP PLC

Appendix 4 1 : n Connection (Multi-drop) App4-1Appendix 4 1 : n Connection (Multi-drop)1 : n ConnectionOne V7 series is connected to multiple PLCs.

Strany 139

App4-2 Appendix 4 1 : n Connection (Multi-drop)Wiring (RS-422/485)For connecting information, refer to the instruction manual for the PLC.Example:Th

Strany 140

Appendix 4 1 : n Connection (Multi-drop) App4-3Notes on Communication ErrorsProcessing for PLC Failure• If a communication error/timeout is detected

Strany 141

App4-4 Appendix 4 1 : n Connection (Multi-drop)Please use this page freely.

Strany 142 - 23. SHINKO ELECTRIC PLC

Appendix 5 Ethernet App5-1Appendix 5 EthernetEthernet• Transferring data in memoryData in memory can be transferred to the V7 series on the Ethernet

Strany 143

App5-2 Appendix 5 Ethernet- Screen data can be transferred from the V-SFT editor on the server to the V7 series.• Communications between the Etherne

Strany 144 - 24. Siemens PLC

Appendix 5 Ethernet App5-3Notes on Ethernet CommunicationsFor V7i:• To use Ethernet communications on V7i, use the 10BASE-T connector (LAN) provided

Strany 145 - S7-300/400MPI

App5-4 Appendix 5 EthernetNames and Functions of Components1. LEDIndicates the status of the communication.2. Port number setting switchesSet the po

Strany 146 - TI500/505, TI500/505 V4

1-12 1. Before Connecting to PLCSystem Memory[Read Area] and [Write Area] must be secured for communications between the V7 series and the PLC.• Set

Strany 147

Appendix 5 Ethernet App5-5Option Unit DU-01SpecificationsPort PositionWhen the DU-01 mounted on the V706, the LAN port faces downward.ItemSpecificati

Strany 148

App5-6 Appendix 5 EthernetWiring10BASE-T Connection• Cable connection diagramStraight cable Cross cable(with HUB) (without HUB)• Notes on cablesUse

Strany 149 - TI500/505 (TI500/505 V4)

Appendix 5 Ethernet App5-7AUI Connection• 10BASE5The following devices are required for 10BASE5 connection:- Coaxial cable for 10BASE5- AUI cable- N-

Strany 150

App5-8 Appendix 5 Ethernet• 10BASE2The following devices are required for 10BASE2 connection:- Coaxial cable for 10BASE2- AUI cable- T-type adaptor-

Strany 151

Appendix 5 Ethernet App5-9Transferring Screen DataThis section describes the procedure for transferring screen data from the V-SFT editor on the serv

Strany 152

App5-10 Appendix 5 EthernetTransferring Screen Data from V-SFT Editor1. Click the [Transfer] icon. The [Transfer] dialog is displayed.2. Attach a c

Strany 153

Appendix 5 Ethernet App5-115. Check the IP address, and click [PC->].6. Data transfer is started.IP address for transfer target

Strany 154 - Wiring Diagram 9

App5-12 Appendix 5 EthernetV-SFT Setting: PLC Type/Communication ParameterTo enable Ethernet communications between the V7 series and a PLC, the fol

Strany 155

Appendix 5 Ethernet App5-13(B) Connecting to the PLC on the Ethernet1. PLC type settingSelect [System Setting] → [PLC Type] and select the PLC that s

Strany 156 - 25. TAIAN PLC

App5-14 Appendix 5 Ethernet2. Communication parameter setting• Select [System Setting] → [Comm. Parameter]. Set the PLC to the V7 series which is c

Strany 157

1. Before Connecting to PLC 1-13• SCRN_No. (n + 2) Screen number commandUse example: To specify a screen number from the PLC:When “D0” is set for [Re

Strany 158 - 26. Telemecanique PLC

Appendix 5 Ethernet App5-15Set the port number (network table number) of the PLC in the [Memory Input] dialog for each part. For more information on

Strany 159

App5-16 Appendix 5 EthernetV-SFT Setting: Network Table EditingTo enable Ethernet communications on the V7 series, the following network table setti

Strany 160 - 27. TOSHIBA PLC

Appendix 5 Ethernet App5-17Starting and Closing• StartingSelect [System Setting] → [Network Table Setting] → [Ethernet]. The network table edit wind

Strany 161

App5-18 Appendix 5 Ethernet- Cancel Monitor RegistrationClick this menu when canceling monitor registration.[View] menuThe items with a check mark a

Strany 162

Appendix 5 Ethernet App5-19[Send Timeout]Set the time-out time for the V7 series to send a EREAD/EWRITE command on the Ethernet.[Port No.] (256 to 65

Strany 163

App5-20 Appendix 5 Ethernet[Sub Net Mask]Attach a check mark ( ) when setting the subnet mask.When this option is checked, it is set to [255.255.255

Strany 164 - 28. TOSHIBA MACHINE PLC

Appendix 5 Ethernet App5-21V-SFT Setting: MacroThis section explains the macro commands (SEND/EREAD/EWRITE) used for the Ethernet. For more informat

Strany 165

App5-22 Appendix 5 Ethernet[EWRITE]Words from the F2 memory are written into the F0 memory in the V7 series of the network table number specified fo

Strany 166 - 29. Toyoda Machine Works PLC

Appendix 5 Ethernet App5-23[SEND]Words from the F0 memory are transferred to the server of the network table number specified for F2. F1 designates

Strany 167 - Screen Editing (Memory Input)

App5-24 Appendix 5 EthernetSystem MemoryThe Ethernet status is output to the system memory ($s) of the V7 series.This section explains the memory ad

Strany 168

1-14 1. Before Connecting to PLC[Write Area] (3 words)*This is an area where the screen status is written.Consecutive three words from the specified

Strany 169

Appendix 5 Ethernet App5-25$s553 Network table 33 status554 Network table 34 status555 Network table 35 status556 Network table 36 status557 Network

Strany 170 - 30. VIGOR PLC

App5-26 Appendix 5 Ethernet$s600 Network table 80 status601 Network table 81 status602 Network table 82 status603 Network table 83 status604 Network

Strany 171

Appendix 5 Ethernet App5-27Addresses• $s514, 515These addresses are related to macro commands [SEND], [EREAD] and [EWRITE].$s514: Sets the executing

Strany 172 - 31. Yamatake PLC

App5-28 Appendix 5 EthernetEthernet Access Functions (HKEtn10.DLL)To enable Ethernet communications between the server and the V7 series, it is nece

Strany 173

Appendix 5 Ethernet App5-29• Notes on use of the sample programsThe data type to be set when creating a program varies depending on whether Visual C+

Strany 174 - 32. Yaskawa Electric PLC

App5-30 Appendix 5 EthernetFunction SpecificationsList• Read• Write• OthersPLC MemoryWordint HKEtn_ReadPlcMemory(WORD *dp,unsigned short Wordcnt,int

Strany 175

Appendix 5 Ethernet App5-31ReadRead Words from PLC Memoryint HKEtn_ReadPlcMemory(WORD *dp,unsigned short Wordcnt,int DeviceType,DWORD addr,char *lpAd

Strany 176

App5-32 Appendix 5 EthernetRead Double-words from PLC Memoryint HKEtn_ReadPlcMemory2(DWORD *dp,unsigned short Wordcnt,int DeviceType,DWORD addr,char

Strany 177

Appendix 5 Ethernet App5-33Read Words from Memory Card Memoryint HKEtn_ReadCardMemory(WORD *dp,unsigned short Wordcnt,int FileNo,int RecordNo,DWORD a

Strany 178

App5-34 Appendix 5 EthernetRead Bits from Internal Memoryint HKEtn_ReadInternalBitMemory(int *lpOnFlag,int DeviceType,DWORD addr,int BitNo,char *lpA

Strany 179

2. Allen-Bradley PLC 2-12. Allen-Bradley PLCAvailable PLCs*1 When using RS-232C ladder transfer cable made by Allen-Bradley, connect the cable shown

Strany 180 - 33. Yokogawa Electric PLC

Appendix 5 Ethernet App5-35WriteWrite Words to PLC Memoryint HKEtn_WritePlcMemory(WORD *sp,unsigned short Wordcnt,int DeviceType,DWORD addr,char *lpA

Strany 181

App5-36 Appendix 5 EthernetWrite Double-words to PLC Memoryint HKEtn_WritePlcMemory2(DWORD *sp,unsigned short Wordcnt,int DeviceType,DWORD addr,char

Strany 182

Appendix 5 Ethernet App5-37Write Words to Memory Card Memoryint HKEtn_WriteCardMemory(WORD *sp,unsigned short Wordcnt,int FileNo,int RecordNo,DWORD a

Strany 183

App5-38 Appendix 5 EthernetWrite Bits to Internal Memoryint HKEtn_WriteInternalBitMemory(int DeviceType,DWORD addr,int BitNo,int OnFlag,char *lpAddr

Strany 184

Appendix 5 Ethernet App5-39Receive Wait from V7int HKEtn_Recvfrom(BYTE *dp,short *lpCnt)This function is retained internally until data is received f

Strany 185

App5-40 Appendix 5 EthernetGet Error Contentsint HKEtn_GetLastError()• Error codes and solutionsCode Contents Solution−1 Undefined command (receive

Strany 186 - Appendix 1 PLC2Way

Appendix 5 Ethernet App5-41Server Communication ProcedureData Request from V7 to Server(1) Execute the receive wait thread using “int HKEtn_RecvFrom(

Strany 187 - V7 series

App5-42 Appendix 5 EthernetError DisplayError messages displayed on the V7 series and those stored in the system memory are explained.Communication

Strany 188

Appendix 5 Ethernet App5-43• System memory: $s518No. Contents Solution0 Normal200 Failed in send requestCheck cable connection and network table sett

Strany 189 - (RS-232C, RS-485/RS-422)

App5-44 Appendix 5 EthernetErrors during Macro Command ExecutionThe execution result of macro commands SEND/EREAD/EWRITE is stored in system memory

Strany 190 - For V7 Series:

2-2 2. Allen-Bradley PLCSLC500 SeriesMicro Logix 1000Available MemoryThe available memory setting range varies depending on the PLC model. Be sure

Strany 191 - V-SFT Setting: System Setting

Appendix 6 Universal Serial Communications App6-1Appendix 6 Universal Serial CommunicationsInterfaceOutline of CommunicationAs shown in the diagram a

Strany 192

App6-2 Appendix 6 Universal Serial CommunicationsDifferences between Connecting to a General-purpose Computer and Connecting to the PLC• Input forma

Strany 193

Appendix 6 Universal Serial Communications App6-3Memory settings (for lamp, data display, etc.) are required during screen creation, and the memory a

Strany 194 - 2nd byte 1st byte

App6-4 Appendix 6 Universal Serial CommunicationsSystem Composition• 1 : 1 connection (one computer, one V series unit)(For wiring, refer to page Ap

Strany 195 - V-SFT Setting

Appendix 6 Universal Serial Communications App6-5Input/Output ConnectorThe connection method for communication between a general-purpose personal com

Strany 196

App6-6 Appendix 6 Universal Serial CommunicationsCN1: RS-232C Connector SpecificationsThe specifications for the RS-232C connector that links to the

Strany 197

Appendix 6 Universal Serial Communications App6-7• Interface connector- Use the following types of RS-232C cable connectors.D-sub 25-pin connector (m

Strany 198

App6-8 Appendix 6 Universal Serial Communications<2-wire system>* Use TC485 (Terminal Converter, optional) when V series is connected on the t

Strany 199

Appendix 6 Universal Serial Communications App6-91 : n Connection* When you go to [Comm. Parameters] under the [System Setting], to [Main2], and chec

Strany 200 - Trend sampling Data sampling

App6-10 Appendix 6 Universal Serial CommunicationsMJ2 (V706 only) Specifications as an RS-232C ConnectorThe pins of modular jack 2 correspond to sig

Strany 201

2. Allen-Bradley PLC 2-3SLC500 Series, Micro Logix 1000PLC-5 Series: Switch Setting1785-KESW1 (Protocol)SW2 (Station number)Set the station number of

Strany 202 - Indirect Memory Designation

Appendix 6 Universal Serial Communications App6-11MJ2 (V706 only) Specifications as an RS-422 ConnectorThe pins of modular jack 2 correspond to signa

Strany 203 - Processing Cycle

App6-12 Appendix 6 Universal Serial Communications1 : n Connection* When you go to [Comm. Parameters] under the [System Setting], to [Main2], and ch

Strany 204 - Notes on Screen Data Transfer

Appendix 6 Universal Serial Communications App6-13<4-wire system>+SD-SD+RD-RD51278SG+SD-SD+RD-RDSG+SD-SD+RD-RD51278SG+SD-SD+RD-RDSG+SD-SD+RD-RD

Strany 205 - System Memory

App6-14 Appendix 6 Universal Serial CommunicationsSystem SettingModel SettingSelect universal serial as the model that will communicate with the V s

Strany 206

Appendix 6 Universal Serial Communications App6-152. The [Comm. Parameter] dialog comes up. In the [Main 1], [Main 2], and [Detail] tab windows, set

Strany 207 - (Fig. b)

App6-16 Appendix 6 Universal Serial Communications• Read AreaThis memory area is necessary when the display screen is changed by a command received

Strany 208 - Multi-link 2

Appendix 6 Universal Serial Communications App6-17- System memory ($s) within internal memory * The switch interrupt information of SW0 and SW1 is wr

Strany 209 - Te rm i na l

App6-18 Appendix 6 Universal Serial Communications- n + 7 (ENT2) entry information 2The entry mode window number where a write operation was execute

Strany 210 - For V706:

Appendix 6 Universal Serial Communications App6-19• Read Clear Escape (Backup) AddressSet the top address for the read clear backup area. The area s

Strany 211

App6-20 Appendix 6 Universal Serial Communications• InterruptThere are five interrupt settings:Switch ON interruptSwitch OFF interruptKeypad interru

Strany 212

2-4 2. Allen-Bradley PLCSW3 (Network link communication speed)Adjust to the settings of the network you are using.SW4 (Reserved)1770-KF2SW1 (Protoco

Strany 213

Appendix 6 Universal Serial Communications App6-21• Data LengthFixed at 8 bits.• Stop BitStop bit settings are shown below.1 bit2 bits• CodeFixed at

Strany 214 - Communication Error

App6-22 Appendix 6 Universal Serial CommunicationsConnection (1 : 1), Transmission Mode (w/ sum check)Used when one host communicates with one V ser

Strany 215

Appendix 6 Universal Serial Communications App6-23<Interrupt Processing (See page App6-38 and page App6-39.)>• Interrupt conditionsAn interrupt

Strany 216 - Multi-link

App6-24 Appendix 6 Universal Serial CommunicationsConnection (1 : 1), Transmission Mode (w/ sum check and CR/LF)Used when one host communicates with

Strany 217

Appendix 6 Universal Serial Communications App6-25<Interrupt Processing (See page App6-38 and page App6-39.)>• Interrupt conditionsAn interrupt

Strany 218

App6-26 Appendix 6 Universal Serial CommunicationsConnection (1 : n), Transmission Mode (w/ sum check)It is possible to attach as many as 32 V serie

Strany 219

Appendix 6 Universal Serial Communications App6-27Connection (1 : n), Transmission Mode (w/ sum check and CR/LF)It is possible to attach as many as 3

Strany 220

App6-28 Appendix 6 Universal Serial CommunicationsData Items for Protocols• Transmission control codeThe transmission control codes are shown in the

Strany 221

Appendix 6 Universal Serial Communications App6-29Response Time and BUSYResponse time varies depending on the type of command.• RM / RI / RCThese com

Strany 222 - 1 : n Connection

App6-30 Appendix 6 Universal Serial CommunicationsGlobal Port Number (FFH)Active for connection mode (1 : n).When the port number is set as [FFH] an

Strany 223 - Wiring (RS-422/485)

PrefaceThank you for selecting the MONITOUCH V7 series.For correct set-up of the V7 series, you are requested to read through this manual to understan

Strany 224 - Notes on Communication Errors

2. Allen-Bradley PLC 2-5SW7 (Network link selection)SW8 (RS-232C/RS-422 selection)SLC500 Series, Micro Logix 100: Transmission Parameter SettingCPU P

Strany 225

Appendix 6 Universal Serial Communications App6-31Read CHR CommandWhen memory contents are in the form of characters when data is read, 1 character (

Strany 226 - Appendix 5 Ethernet

App6-32 Appendix 6 Universal Serial CommunicationsRead Memory CommandNote: Due to the fact that communication speed is increased when you use the re

Strany 227 - Ethernet

Appendix 6 Universal Serial Communications App6-33Write CHR CommandWhen memory contents are in the form of characters, it is necessary to use a write

Strany 228 - IP Address for the V7 Series

App6-34 Appendix 6 Universal Serial CommunicationsWrite Memory CommandNote: Due to the fact that communication speed is increased when you use the w

Strany 229 - ADR - LOW - HI

Appendix 6 Universal Serial Communications App6-35Retry CommandUse this command when a write command/write CHR command is sent and an NAK error code

Strany 230 - Option Unit DU-01

App6-36 Appendix 6 Universal Serial CommunicationsInterrupt Setting Command• Interrupt setting command- Host sideInterrupt conditions can be specifi

Strany 231 - 10BASE-T Connection

Appendix 6 Universal Serial Communications App6-37Interrupt Status Read Command• Interrupt status read command- Host sideInterrupt status is read.Dat

Strany 232 - Repeater

App6-38 Appendix 6 Universal Serial CommunicationsInterrupt (ENQ)When interrupt is used when the connection mode is (1 : 1)*, this code is transmitt

Strany 233

Appendix 6 Universal Serial Communications App6-39It is possible to use a macro command to initiate an interrupt.There are two ways to use a macro co

Strany 234 - Transferring Screen Data

App6-40 Appendix 6 Universal Serial CommunicationsSwitch Output (See page App6-16, page App6-23 and page App6-38.)When [Output Action] of a switch i

Strany 235

2-6 2. Allen-Bradley PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2TXDRXDPLCRTSCTS23456DSRSG 781113DC

Strany 236 - 6. Data transfer is started

Appendix 6 Universal Serial Communications App6-41The switch number is written in the following way in write areas n + 3 and n + 4.When the MONITOUCH

Strany 237 - Application

App6-42 Appendix 6 Universal Serial Communications09H: Received data overThe number of write command data received from the host exceeded that of da

Strany 238

Appendix 6 Universal Serial Communications App6-431-byte Character Code List2SP!"#$%&’()+,./30123456789:;<=>?4@ABCDEFGHIJKLMNO5PQRSTUV

Strany 239

App6-44 Appendix 6 Universal Serial CommunicationsMemory MapMemoryInside the V series, there is internal memory necessary for screen display called

Strany 240 - Appendix 5 Ethernet App5-15

Appendix 6 Universal Serial Communications App6-45System Memory ($s)System memory is memory that writes V series action status when the V Series is c

Strany 241

App6-46 Appendix 6 Universal Serial Communications• Address 0080 to 0095The [Output Memory] of a switch is assigned to bits in this area.Set [Output

Strany 242 - Menu and Icons

Appendix 6 Universal Serial Communications App6-47Switch ON Macro ActionThe macro command that controls a repeat function in the switch ON macro, as

Strany 243 - Editing the Network Table

App6-48 Appendix 6 Universal Serial CommunicationsPlease use this page freely.

Strany 244

Appendix 7 V-Link App7-1Appendix 7 V-LinkV-Link• “V-Link” is the network where the computer reads from and writes to the internal memory of the V7 se

Strany 245 - 255. 255

App7-2 Appendix 7 V-LinkWiringCableUse Hakko Electronics’ cable “V6-TMP” (3 m) for connection with a computer.The shielded cable of V6-TMP is connec

Strany 246 - Macro Command

2. Allen-Bradley PLC 2-7Wiring Diagram 3Wiring Diagram 4DCDRXDTXDDTR12345COMDSR 678RTSCTSPLC123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cable

Strany 247

Appendix 7 V-Link App7-3RS-485 (V7 series: maximum 31 sets)Wiring example of above (a) and (b)CN1CN1CN1MJ2/1MJ2/1 MJ2/1abV6-TMPRS-232CRS-422RS-485PLC

Strany 248

App7-4 Appendix 7 V-LinkV-SFT SettingThe V-SFT settings required for V-Link are explained.V-Link Setting1. Click [System Setting] → [V-Link Setting]

Strany 249

Appendix 7 V-Link App7-5ProtocolRead (with sum check and CR/LF)STXCommandResponse(Normal communication)Read Command*11111111222222218441221112STXACKS

Strany 250 - Appendix 5 Ethernet App5-25

App7-6 Appendix 7 V-LinkWrite (with sum check and CR/LF)1111222218440064H30H31H02HBA 2102H03H30H30H36H34H41H42H31H32H34H32H34H31H33H32H33H31H01H02H3

Strany 251 - App5-26 Appendix 5 Ethernet

Appendix 7 V-Link App7-7Data Items for Protocols• Transmission control code: 1 byte• V7 port number: 2 bytesPort numbers are used so that the host co

Strany 252 - Addresses

App7-8 Appendix 7 V-Link- Expansion codeSet the slot number of the CPU memory of the MITSUBISHI PLC or the CPU number of the YOKOGAWA PLC.Example:MI

Strany 253 - Sample Folder

Appendix 7 V-Link App7-9NAK: Error Codes02H: Overrun/Framing errorAn overrun or framing error is detected in the received data.Send the command again

Strany 254

App7-10 Appendix 7 V-Link1-byte Character Code List2SP!"#$%&’()+,./30123456789:;<=>?4@ABCDEFGHIJKLMNO5PQRSTUVWXYZ[]^_6’abcdefghijklmn

Strany 255 - Function Specifications

List-1Connection Compatibility ListV712/V710/V708/V706+DU-01• 1 : 1...One set of the V7 series is connected to one PLC (

Strany 256 - Read Words from PLC Memory

List-2 *1 When the V7 series is connected to the PLC on a controller network, it is possible to perform communications with other PLCs on the same n

Strany 257

2-8 2. Allen-Bradley PLCWiring Diagram 5RS-422Wiring Diagram 6PLCRDSDRS2CD 134GND 5DR 6RS 7CS 8MicroLogix1000123457SDRDRSCSSGSHELL875*1* Use shielde

Strany 258 - Read Bits from PLC Memory

List-3V706• 1 : 1...One set of the V706 series (MJ2) is connected to one PLC (1:1 connection).• 1 : n...

Strany 259

List-4 *1 When the V7 series is connected to the PLC on a controller network, it is possible to perform communications with other PLCs on the same n

Strany 260 - Write Words to PLC Memory

402000002200NE0Hakko Electronics Co., Ltd.890-1, Kamikashiwano-machi, Matto-shi, Ishikawa, 924-0035 JapanTEL (076)274-2144 FAX(076)274-5208TE

Strany 261

2. Allen-Bradley PLC 2-9Wiring Diagram 7TXDRXDPLCCOMRXD+12569TXD+1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D-sub 9-pin (ma

Strany 262 - Write Bits to PLC Memory

2-10 2. Allen-Bradley PLCPlease use this page freely.

Strany 263 - Others Functions

3. Automationdirect PLC 3-13. Automationdirect PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and

Strany 264 - Get Source’s IP Address

3-2 3. Automationdirect PLCAvailable MemoryThe available memory setting range varies depending on the PLC model. Be sure to set within the range av

Strany 265 - Get Error Contents

3. Automationdirect PLC 3-3Wiring Diagram 2Wiring Diagram 3SGPLCRxDTxD134654321123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.Modular con

Strany 266

3-4 3. Automationdirect PLCWiring Diagram 4RS-422Wiring Diagram 5TXDRXDPLC0V2313123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.D-sub 15-

Strany 267

Notes on Safe Use of MONITOUCHIn this manual, you will find various notes categorized under the following levels with the signal words “DANGER,” and “

Strany 268 - • System memory: $s518

3. Automationdirect PLC 3-5Wiring Diagram 6TXD3+TXD3−PLCRXD3+RXD3−12132425SG 71712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D-

Strany 269 - App5-44 Appendix 5 Ethernet

3-6 3. Automationdirect PLCPlease use this page freely.

Strany 270

4. Baldor PLC 4-14. Baldor PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are as

Strany 271

4-2 4. Baldor PLCWiringWiring diagram with the PLC is shown below.RS-232CWiring Diagram 1PLCRXDTXDDTRSG2345DSRRTSCTS678123SDRDSHELL87*17SG5* Use shi

Strany 272

5. DELTA PLC 5-15. DELTA PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are as f

Strany 273 - System Composition

5-2 5. DELTA PLCWiringWiring diagram with the PLC is shown below.RS-485Wiring Diagram 1+PLC-1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist

Strany 274 - Input/Output Connector

6. FANUC PLC 6-16. FANUC PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are as f

Strany 275 - 1 2 3 4 5 6 7 8 9 10 11 12 13

6-2 6. FANUC PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1RS-422Wiring Diagram 2SDBPLCJD42RDB1790V18123457SDRDRSCSSG

Strany 276

6. FANUC PLC 6-3Wiring Diagram 3PLCJD40RXDTXD13245RTS67CTS8*CTS*RTS*TXD*RXD120V1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D

Strany 277

6-4 6. FANUC PLCPlease use this page freely.

Strany 278

• Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found. Failure to do so may lead to fire

Strany 279 - 12345678

7. FATEK AUTOMATION PLC 7-17. FATEK AUTOMATION PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and

Strany 280

7-2 7. FATEK AUTOMATION PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2RTS1RXD1CTS1SG1346TXD1 2PLC1234

Strany 281

7. FATEK AUTOMATION PLC 7-3RS-422Wiring Diagram 3SGD+DPLC1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D-sub 25-pin (male)RJ-4

Strany 282 - <4-wire system>

7-4 7. FATEK AUTOMATION PLCPlease use this page freely.

Strany 283 - System Setting

8. Fuji Electric PLC 8-18. Fuji Electric PLCAvailable PLCs*1 To use FLEX-PC of Toyota version, select [FLEX-PC (T)].*2 To use FLEX-PC CPU of Toyota v

Strany 284 - Setting Items

8-2 8. Fuji Electric PLCFLEX-PC COM (T) (NJ Computer Link) Toyota VersionMICREX-F Series, SPB (N Mode) & FLEX-PC Series: Switch SettingMODE swit

Strany 285

8. Fuji Electric PLC 8-3Available MemoryThe available memory setting range varies depending on the PLC model. Be sure to set within the range availa

Strany 286

8-4 8. Fuji Electric PLCSPB (N Mode) & FLEX-PC Series, SPB (N Mode) & FLEX-PC CPU PortFLEX-PC COM (T) (NJ Computer Link) Toyota VersionStand

Strany 287

8. Fuji Electric PLC 8-5WiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2SDRDRSCSDRPLC23456SGCD78123457SDRDR

Strany 288

8-6 8. Fuji Electric PLCRS-485Wiring Diagram 3RS-422Wiring Diagram 4SDASDBRDARDBSGPLC1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair c

Strany 289 - <2-wire system>

[General Notes]• Never bundle control cables and input/output cables with high-voltage and large-current carrying cables such as power supply cables.

Strany 290 - Standard Type Protocol

9. GE Fanuc PLC 9-19. GE Fanuc PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series ar

Strany 291 - When the host writes

9-2 9. GE Fanuc PLCAvailable MemoryThe available memory setting range varies depending on the PLC model. Be sure to set within the range available

Strany 292

9. GE Fanuc PLC 9-3WiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1RS-485Wiring Diagram 2SDPLCRDRS2345CS7GND123457SDRDRSCSS

Strany 293

9-4 9. GE Fanuc PLCWiring Diagram 3RTS(A)PLC0VCTS(B’)6789RT101112RD(A’)RD(B’)SD(A)SD(B)RTS(B)CTS(A’)1314151712132425SG+SD-SD+RD-RD51278SHELL*1* Use

Strany 294

10. Hitachi PLC 10-110. Hitachi PLCAvailable PLCs*1 When using the HITACHI’s EH-RS05 or CNCOM-05 cable, connect the cable shown in [Wiring Diagram 1]

Strany 295

10-2 10. Hitachi PLCCPU ModuleThe peripheral port setting should be “transmission control protocol 1 without port.” No other setting is available.H

Strany 296

10. Hitachi PLC 10-3HIDIC-S10/2αHIDIC-S10/ABSMemory TYPE RemarksFW (work register) 0X (input relay) 1 XW as word deviceY (output relay) 2 YW as word

Strany 297 - H 46H 32H 41H

10-4 10. Hitachi PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2RDCS35SDRSSD 2RDCSFG 1SG 7DRPHLSGPV122

Strany 298 - Response Time and BUSY

10. Hitachi PLC 10-5Wiring Diagram 3RS-422Wiring Diagram 4RDSDERSGDRRSCS2CD 1345678PLC123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.D-su

Strany 299 - Global Port Number (FFH)

10-6 10. Hitachi PLCWiring Diagram 5When connecting to the S10xα series, add a resistor of 50 Ω (1/2 W) as shown below.URX HUTX HURX LPLCUTX L50501S

Strany 300

ContentsPrefaceNotes on Safe Use of MONITOUCH1. Before Connecting to PLCTypes of Connection...

Strany 301

11. IDEC PLC 11-111. IDEC PLCAvailable PLCs* When using RS-232C cable “FC2A-KC2” made by IDEC, connect the cable shown in [Wiring Diagram 3] to the D

Strany 302 - WORDWORDWORDWORD

11-2 11. IDEC PLCWiringWiring diagram with the PLC is shown below.RS-232CWiring Diagram 1PLCSDRDER2CD 134GND 5DR 6RS 7CS 8123457SDRDRSCSSGSHELL875*1

Strany 303 - WORDWORD

12. KEYENCE PLC 12-112. KEYENCE PLCAvailable PLCs*1 For connection to MJ2 of a V706, use an MJ2-PLC adaptor plus KZ-C20 and MB-CPUQ.*2 To connect KZ-

Strany 304 - • Retry command

12-2 12. KEYENCE PLCCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are as follows:KZ Series Link

Strany 305 - 0001020304050607

12. KEYENCE PLC 12-3KV-700 CPU*1 Maximum baud rate available is 57600 bps. Select the appropriate baud rate depending on the used PLC and environmen

Strany 306

12-4 12. KEYENCE PLCAvailable MemoryThe available memory setting range varies depending on the PLC model. Be sure to set within the range available

Strany 307 - SW0 SW1 ENT0 ENT1 ENT2

12. KEYENCE PLC 12-5WiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2SDPLCRD234RSCSSG57123457SDRDRSCSSGSHELL

Strany 308 - WORD WORD

12-6 12. KEYENCE PLCWiring Diagram 3Wiring Diagram 4SDCSPLCSGRDRS31456123456123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.D-sub 25-pin

Strany 309

12. KEYENCE PLC 12-7Wiring Diagram 5RS-422Wiring Diagram 6PLC345RDSDSG123456123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.Modular jack,

Strany 310 - Error Codes

12-8 12. KEYENCE PLCPlease use this page freely.

Strany 311

10. Hitachi PLCAvailable PLCs ...

Strany 312 - 1-byte Character Code List

13. KOYO ELECTRONICS PLC 13-113. KOYO ELECTRONICS PLCAvailable PLCs*1 When connecting to MJ2 on the V706, use an MJ2-PLC adaptor plus the designated

Strany 313 - Memory Map

13-2 13. KOYO ELECTRONICS PLCCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are as follows:Avail

Strany 314 - System Memory ($s)

13. KOYO ELECTRONICS PLC 13-3Switch SettingU-01DMOn-line/Off-line switch: On-lineUNIT ADR switch: “0” for ×10, “1” for ×1SW4 DIP switch:SW5 DIP switc

Strany 315

13-4 13. KOYO ELECTRONICS PLCG-01DMOn-line/Off-line switch: On-lineShort plug 1: openShort plug 2: RS-232C . . . . . ENABLERS-422 . . . . . . DISENA

Strany 316 - Switch action flowchart

13. KOYO ELECTRONICS PLC 13-5WiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2SDRDPLCRSCSSG23457123457SDRDRS

Strany 317

13-6 13. KOYO ELECTRONICS PLCRS-422Wiring Diagram 3Wiring Diagram 4+RTS−RTSPLC+CTS−CTS+OUT−OUT−IN+IN−IN+IN101112131415161724251500V 71712132425SG+SD

Strany 318

13. KOYO ELECTRONICS PLC 13-7Wiring Diagram 5Wiring Diagram 6T1T2PLCT3FG1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D-sub 25

Strany 319

13-8 13. KOYO ELECTRONICS PLCWiring Diagram 7Wiring Diagram 8RXD+RXDPLCCTS1+TXD1+TXD1RTS1+RTS1CTS1+910111416181923SG 71712132425SG+SD-SD+RD-RD51278S

Strany 320 - RS-232C →

14. LG PLC 14-114. LG PLCAvailable PLCsCommunication SettingThe recommended communication parameter settings of the PLC and the V7 series are as foll

Strany 321

14-2 14. LG PLCMASTER-KxxxS CNET / GLOFA CNET / GM Series CPUAvailable MemoryThe available memory setting range varies depending on the PLC model.

Strany 322 - Protocol

20. SAIA PLCAvailable PLCs ...

Strany 323 - App7-6 Appendix 7 V-Link

14. LG PLC 14-3MASTER-KxxxSMASTER-KxxxS CNETGLOFA CNET / GM Series CPUMemory TYPE RemarksP (input/output relay) 0 Input: Read onlyM (auxiliary relay)

Strany 324 - Data Items for Protocols

14-4 14. LG PLCWiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2PLCRXDTXDGND235123SDRDSHELL87*17SG 5* Use s

Strany 325 - Response Code: 2 bytes

14. LG PLC 14-5Wiring Diagram 3Wiring Diagram 4PLCRXDTXDGND235RTSCTS78123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.D-sub 25-pin (male)D

Strany 326 - NAK: Error Codes

14-6 14. LG PLCWiring Diagram 5RS-422Wiring Diagram 6PLCRXDSGTXD457123SDRDSHELL87*17SG 5* Use shielded twist-pair cables.D-sub 9-pin (male)D-sub 25-

Strany 327

14. LG PLC 14-7Wiring Diagram 7RDARDBPLCSGSDASDB1712132425SG+SD-SD+RD-RD51278SHELL*1* Use shielded twist-pair cables.D-sub 25-pin (male)RJ-45 8-pinV

Strany 328

14-8 14. LG PLCPlease use this page freely.

Strany 329 - List-2

15. Matsushita Electric Works PLC 15-115. Matsushita Electric Works PLCAvailable PLCs*1 For connection to MJ2 of a V706, use an MJ2-PLC adaptor plus

Strany 330 - February, 2004

15-2 15. Matsushita Electric Works PLCMEWNET: Link Unit Switch SettingAvailable MemoryThe available memory setting range varies depending on the PLC

Strany 331 - List-4

15. Matsushita Electric Works PLC 15-3WiringWiring diagrams with the PLC are shown below.RS-232CWiring Diagram 1Wiring Diagram 2PLCSDSGCD278ER 9RS 4C

Strany 332 - Hakko Electronics Co., Ltd

15-4 15. Matsushita Electric Works PLCWiring Diagram 3RS-422Wiring Diagram 4PLCSDSGRD123457SDRDRSCSSGSHELL875*1* Use shielded twist-pair cables.D-su